Specialized in Manufacturing the Arc dividers, Arc Chambers & Arc Chutes used in high voltage applications. Our Range of non-asbestos, high temperature composites have proven to be successful in transportation & power switch gear applications of Indian Railways.
Non-asbestos & Glass Bonded Mica Based Arc Chutes have the ability to withstand high voltage current as well as the shocks & vibrations associated with the rigors of these applications. Test Specification as per IEC 60947 parts & sub-parts, in correspondence with RDSO/LKO Specification No. MP-0.23.02.01 DEC 99 (Rev.00) &CLW/CRJ SPECN. NO:
Features:
- Non-combustible
- Superior Heat & Arc Resistance Characteristics
- Excellent Mechanical Strength & Electrical Properties at elevated temperatures
Our Range of Arc Chutes/Chambers includes:
- Arc Chute for Motor (Line) Contactor of Conv. Electric Locomotives
- Conv. Thermal current (Ith) :1500 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper& Brass.
- Mechanical endurance: 5 million operating cycles (min.)
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 5k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
2.Arc Chute for Shunting Contactor of Conv. Electric Locomotives
- Conv. Thermal current (Ith):700 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper& Brass
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse: Min. 2k Volts/mm
Surface:Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
3.Arc Chute for Braking Excitation Contactor of Conv. Electric Locomotives
- Conv. Thermal current (Ith) :1000 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper& Brass
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
4.ArcChutefor C-118&EM Contactor of Conv. Electric Locomotives
- Conv. Thermal current (Ith) :500 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper& Brass
- Mechanical endurance: 5 million operating cycles (min)
- Pollution degree (IEC 60947-1): PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity: 180 seconds
- Di-electric Strength: Transverse: Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
5.Arcing Chamber for N-32 Tap Changer of Conv. Electric Locomotives
- Conv. Thermal current (Ith):3000 A
- Materials - Insulating parts GLASS BONDED MICA BASED
Contacts PiecesCopper-ETP
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+ 500°C
6.Arc Chutefor Power Contactor of Diesel Locomotives (ALCO)
- Conv. Thermal current (Ith):1200 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+ 500°C
7.Arc Chutefor Cranking Contactor of Diesel Locomotives (ALCO)
- Conv. Thermal current (Ith):1000 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+ 500°C
8.Arc Chute for GF Contactor ofDiesel Locomotives (ALCO)
- Conv. Thermal current (Ith):500 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+ 500°C
9.Arc ChuteComplete for HSCB Contactor similar to AEG Germany make for Metro Railways
- Conv. Thermal current (Ith):1500 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+ 500°C
10.Arc Chute for GFD Contactor of EMD Locomotive (HHP)
- Conv. Thermal current (Ith) :200 A / 600 V DC
- Materials - Insulating parts Thermosetting moulded Plastic
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
11.Arc Chute for DB Contactor of EMD Locomotive (HHP)
- Conv. Thermal current (Ith) :1600 A / 1500 V DC
- Materials - Insulating parts Thermosetting moulded Plastic
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
12.Switching Element for EMD Locomotive (HHP)
- Conv. Thermal current (Ith) - 250 A
- Materials - Insulating parts CompressionMoulded Plastic
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation voltage UI : 1,000 V (When mounted individually, with actuator made from plastic and normal contact gap)
400 V (When mounted in series with minimum clearance 28- and 32-mm resp.)
- Minimum Arc Resistance Capacity: 180 seconds
- Di-electric Strength: Transverse: Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
13.Arc Chamber for Radiator Cooling Fan Contactor of EMD Locomotive (HHP)
- Conv. Thermal current (Ith) :250 A
- Materials - Insulating parts CompressionMoulded Plastic
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity: 180 seconds
- Di-electric Strength: Transverse: Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range:-10.....+250°C
14.Arc Chute for BPS Contactor of 3PH Electric Locomotive
- Conv. Thermal current (Ith) :BPS 15.15c – (1500 A / 1500 V) & BPS 30.06 (3000 V / 600 A)
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1) : PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity : 180 seconds
- Di-electric Strength: Transverse : Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C
15.Arc Chute for HSM Contactor of 3PH Electric Locomotives
- Conv. Thermal current (Ith) :250 A
- Materials - Insulating parts NON-ASBESTOS BASED
Contacts PiecesCopper
- Mechanical endurance: 5 million operating cycles min.
- Pollution degree (IEC 60947-1): PD4
- Rated insulation resistance: 2k? @ 1000 VDC
- Minimum Arc Resistance Capacity: 180 seconds
- Di-electric Strength: Transverse: Min. 2k Volts/mm
Surface: Min. 118 kV
- Flammability Nature: Yes
- Temperature range: -10.....+250°C